Cooper36 Channel Unit

 

Product specification

TRANSFORMER CORE

  • Three phase, forced air cooled, class H, 50kVA
  • Primary winding connected in Delta
  • Secondary winding connected in Star
  • Auxiliary winding: 110V a.c. 3.3kVA single phase

PRIMARY SUPPLY

  • Primary voltage: 380V, 415V, 440V
  • Primary current: 76A, 70A, 66A
  • Frequency: 50/60 Hz

PROTECTION

  • Three phase 80A circuit breaker with shunt trip
  • Three primary core winding over temperature thermostats linked to circuit breaker shunt trip

SECONDARY OUTPUTS

  • Output: 32.5V for 30V heating element operation
  • Auxiliary outputs: Two 110V, 10A, 50/60Hz output sockets
  • Number of temperature controlled output channels: 36 channels
  • Maximum load per output channel: 1.35kW
  • Maximum current per output channel: 45A

CONSTRUCTION

  • Case: 304 Stainless Steel case fitted with four 150mm nylon wheels

DIMENSIONS

  • Weight: 362kg
  • Height: 1420mm
  • Width: 680mm
  • Depth: 665mm

SWITCHING

  • 36 single pole, 80A, contractors with 110V a.c. coil

TEMPERATURE CONTROL

  • Temperature measurement, display and control: Fahrenheit or Centigrade
  • Temperature ramp up and down in degrees per hour
  • Hold/soak temperature set point and hold/soak time period setting